存儲150組測試結(jié)果紅外遙控打印方式內(nèi)置電池連續(xù)工作8個小時(shí)
KM900的技術(shù)參數(shù)及型號選擇
KM900 型號 | 參 數(shù) | 分辨率 | 精 度 | 范圍 | |||||
C | S | N | CS | SN | CN | ||||
√ | √ | √ | √ | √ | √ | 煙道溫度 | 1.0℃ | +2.0℃ 讀數(shù)+0.3% | 0 ~600℃ |
√ | √ | √ | √ | √ | √ | 環(huán)境溫度 | 1.0℃ | +1.0℃ 讀數(shù)+0.3% | 0 ~50℃ |
|
|
|
|
|
| 氣體測量 |
|
|
|
√ | √ | √ | √ | √ | √ | O2 | 0.1% | +0.2% | 0 ~21.0% |
√ |
|
| √ |
| √ | CO | 1ppm, mg/m3 | + 20ppm <400ppm + 5% <5000ppm +10% >5000ppm | 0 ~10000ppm |
| √ |
| √ | √ |
| SO2 | 1ppm, mg/m3 | + 5ppm<100ppm +5% >100ppm | 0 ~5000ppm |
|
| √ |
| √ | √ | NO | 1ppm, mg/m3 | +5ppm<100ppm +5% >100ppm | 0 ~5000ppm |
√ | √ | √ | √ | √ | √ | 靜壓 | 0.1mbar | 量程+5% | 150mbar |
√ | √ | √ | √ | √ | √ | 動壓 | 0.1mbar | 量程+5% | 150mbar |
|
|
|
|
|
| 自動計(jì)算 |
|
|
|
√ | √ | √ | √ | √ | √ | CO2 | 0.1% | 讀數(shù)+0.3% | 0 ~99.9% |
|
|
|
|
|
| NOx | 1ppm, mg/m3 |
| 0 ~5000ppm |
√ | √ | √ | √ | √ | √ | 凈溫度 | 0.1℃ | +2.0℃ 讀數(shù)+0.3% | 0 ~600℃ |
√ | √ | √ | √ | √ | √ | 過空氣系數(shù) | 0.1% | +0.2% | 0 ~2885.0% |
√ | √ | √ | √ | √ | √ | CO/CO2比率 | 0.0001 | +0.0001 | 0 ~0.9999 |
√ | √ | √ | √ | √ | √ | 燃燒效率 | 0.1% | 讀數(shù)+1.0% | 0 ~99.9% |
內(nèi)置燃料表:天然氣 煤氣 輕油 重油 丙烷 丁烷 無煙煤 焦炭 硬煤
主機(jī)尺寸:220mm x 55mm x 120mm 主機(jī)重量:1Kg標(biāo)準(zhǔn)探針:長度350mm x 直徑8mm , 3m導(dǎo)管
基礎(chǔ)配置:主機(jī) 350mm煙氣探針充電器 便攜背包
充電器:220V
蓄電池使用時(shí)間:滿充電后>8小時(shí)
選件:KMCLP12-1200mm長煙道探針 KMIRP-紅外接收便攜打印機(jī)