浮頂罐伸縮式靜電接地裝置/中低頻雷電分流器,浮頂罐伸縮式靜電接地裝置,是針對(duì)浮頂儲(chǔ)罐靜電接地而研發(fā),實(shí)現(xiàn)罐壁與浮盤之間可靠的等電位連接,為雷電流和束縛電荷的安全泄放提供最低阻抗通道,同時(shí)降低浮盤和罐壁之間的瞬時(shí)過(guò)電壓,成數(shù)量級(jí)的降低可燃?xì)怏w被點(diǎn)燃的概率,保護(hù)密封環(huán)形間距不會(huì)產(chǎn)生電弧,將可燃?xì)怏w產(chǎn)生火花的可能性降到最低。
國(guó)際旁路導(dǎo)體----援引美國(guó)API標(biāo)準(zhǔn):
美國(guó)API標(biāo)準(zhǔn)中,對(duì)于儲(chǔ)罐的靜電接地,要求設(shè)有旁路導(dǎo)體,援引參考如下:
第4.2.1.2.2條: The tank floating roof shall be bonded to the tank shell by direct electrical connection through an appropriate number of bypass conductors. Each conductor, including connections, shall have a maximum end-to-end electrical resistance of 0.03Ω . The bypass conductors shall be of the minimum length necessary to permit full movement of the floating roof. Bypass conductors should be evenly spaced not more than every 30 m (100 ft) around the tank circumference with a minimum of two.
譯:浮盤和罐壁之間需用適當(dāng)數(shù)量的旁路導(dǎo)體作直接的電氣連接。包括接點(diǎn)的每個(gè)導(dǎo)體兩端的最大電阻為0.03Ω 。在浮盤所有升降狀態(tài)時(shí)旁路導(dǎo)體必須保持最小長(zhǎng)度。旁路導(dǎo)體的平行間距不得大于30米儲(chǔ)罐圓周,最少需要兩條。
技術(shù)參數(shù):
1. 編帶長(zhǎng)度:20米或24米(兩種規(guī)格)
2. 編帶寬度:4.8cm
3. 編帶厚度:3mm
4. 承受拉力:20kg
5. 產(chǎn)品重量:30kg
6. 殼體壁厚(平均):4mm
7. 殼體材質(zhì):不銹鋼304或316L
8. 導(dǎo)線電阻:小于25mΩ
使用場(chǎng)合:
1、原油儲(chǔ)罐罐頂;
2、外浮頂罐罐頂;
1、 降低雷擊風(fēng)險(xiǎn);
中低頻雷電分流器,采用伸縮式導(dǎo)線設(shè)計(jì),可以實(shí)現(xiàn)罐壁與浮盤之間的可靠等電位連接,并且在任何時(shí)候,保持罐壁與浮盤間的距離最短,連接導(dǎo)線始終具有最小電阻值,為雷電流和束縛電荷的泄放提供最低阻抗通道,同時(shí)降低浮盤和罐壁之間的瞬時(shí)過(guò)電壓,保護(hù)密封環(huán)形間距不會(huì)產(chǎn)生電弧,將儲(chǔ)罐遭遇雷擊起火的可能性降到最低。
2、 外浮頂罐的最佳選擇;
外浮頂儲(chǔ)罐浮頂與罐壁之間的雷電流泄放主要方式是: 1、浮梯連接油罐的罐壁和浮盤; 2、斜梯側(cè)設(shè)置2根25mm2軟銅復(fù)鉸線;
浮梯在浮盤升降輪軸沿浮盤上的軌道滾動(dòng),接觸電阻大且隨浮盤表面的銹蝕會(huì)更大。另外,油罐罐體的罐壁內(nèi)側(cè)有一層蠟,膠質(zhì)及其他有機(jī)成分的混合物,將罐體的罐壁金屬表面覆蓋,金屬靜電導(dǎo)觸片和罐體的罐壁金屬表面被這層覆蓋物絕緣,有較大的電阻,從而在相當(dāng)程度上失去導(dǎo)電荷的作用。
中低頻雷電分流器安裝簡(jiǎn)單,無(wú)需維護(hù),連接可靠,在國(guó)外原油外浮頂罐的防雷保護(hù)中,應(yīng)用較為普遍,近些年在國(guó)內(nèi)市場(chǎng)逐漸普及,是外浮頂罐防雷的選擇。
使用示意圖;