自動絕緣耐壓測試儀 CS56
耐壓測試 | |||||||
型號 | 輸出電壓 | 測試電流 | 測試時(shí)間 | 變壓器容器 | 精確度 | ||
CS5600 | (0.10~5.00)kV(AC) | (0.100~100.0)mA(AC) | (0.1~999)s | 500VA | ±(2%+2count) | ||
CS5601 | (0.10~5.00)kV(AC/DC) | (0.100~100.0/20.00)mA(AC/DC) | (0.1~999)s | 500VA | ±(2%+2count) | ||
CS5602 | (0.10~5.00)kV(AC) | (0.100~20.00)mA(AC) | (0.1~999)s | 100VA | ±(2%+2count) | ||
CS5603 | (0.10~5.00)kV(AC/DC) | (0.100~20.00/10.00)mA(AC/DC) | (0.1~999)s | 100VA | ±(2%+2count) | ||
絕緣電阻 | |||||||
型號 | 輸出電壓 | 電阻范圍 | 測試時(shí)間 | 精確度 | |||
CS5600 | 100V/250V/500V/1000V | (1~9999)MΩ | (0.1~999)s | ±(5%+2count) | |||
CS5601 | 100V/250V/500V/1000V | (1~9999)MΩ | (0.1~999)s | ±(5%+2count) | |||
CS5602 | 100V/250V/500V/1000V | (1~9999)MΩ | (0.1~999)s | ±(5%+2count) | |||
CS5603 | 100V/250V/500V/1000V | (1~9999)MΩ | (0.1~999)s | ±(5%+2count) | |||
外型尺寸 | 寬×高×深=320mm×150mm×350mm(CS5600/CS5601) 寬×高×深=320mm×150mm×290mm(CS5602/CS5603) |
·CS5600、CS5601、CS5602、CS5603為新一代安全防護(hù)式智能型耐壓/絕緣測試儀,均采用MCU控制技術(shù)、能實(shí)時(shí)顯示絕緣電阻值與擊穿電壓值、電流值,可以直觀、準(zhǔn)確、快速、可靠地測試各種被測對象的擊穿電壓、漏電流 SYT-2000 Ф4×300mm Φ6×500 mm Φ6×800 mm Φ8×1.0mm Ф10×1.5m Ф12×2.0m Φ12×2.5 m Ф6×300mm Φ6×500mm Φ10×1.0m Φ12×1.5m YB150A、絕緣品質(zhì)等電氣安全性能指標(biāo),并可以作為交(直)流高電壓源用來測試元器件和整機(jī)性能。配備RS232(或RS485)通信口以及PLC所需的信號輸入、輸出接口,可方便地與計(jì)算機(jī)或PLC組成綜合測試系統(tǒng)。能夠快速、準(zhǔn)確地測量電子元器件、家用電器、絕緣材料、儀器儀表、照明電器、電動電熱器具的絕緣電阻與耐壓強(qiáng)度。
性 能 特 點(diǎn) |
·安全防電墻檢測功能,可保護(hù)操作人員、測試設(shè)備、被測體的安全·本測試儀采用VFD(熒光數(shù)碼)顯示,醒目、美觀,實(shí)時(shí)顯示各測量參數(shù)·本系列儀器采用高速A/D采樣,測量更加快捷準(zhǔn)確·地線回路端開路檢測功能,Danger指示燈 ·過零啟動、過零切斷功能,防止正反向過沖·與傳統(tǒng)機(jī)型相比絕緣電阻范圍、測試電壓量程寬,電阻范圍可達(dá)9999MΩ·耐壓→絕緣,絕緣→耐壓 可自動轉(zhuǎn)換;絕緣測試可自動切換量程·可記錄、保存測試數(shù)據(jù)·針對被測對象電容、電感分布參數(shù),增加設(shè)置絕緣測試報(bào)警延遲時(shí)間功能·±2%高精度,高穩(wěn)定性,測試時(shí)間范圍廣:(0.1-999)s·標(biāo)配PLC接口,選配RS232、RS485接口
產(chǎn)品附件 |
◆ 隨機(jī)附件 CS26009-1 CS26009-2 CS26009-3 CS26031-1◆ 選配附件 CS26023-1
日本日置3174 AC自動絕緣耐壓測試儀廠家 | |
【耐壓測試】 | |
輸出電壓 | AC0.2~5.00kV |
電壓設(shè)置方式 | 數(shù)字設(shè)置,設(shè)置分辨率:0.01kV |
AC波形/頻率 | 正弦波(無負(fù)載時(shí)畸變率在5%以下),可以在50/60Hz切換 |
電流測量范圍 | 0.01mA~20.0mA,真有效值顯示(數(shù)字) |
測量量程 | 10mA,分辨率:0.01mA / 100mA,分辨率:0.1mA |
電壓計(jì) | 精度:±1.5%rdg.(1000V以上),±15V(1000V以下)(有效值顯示) |
判定方式 | 窗口比較方式(數(shù)字設(shè)定) |
【絕緣電阻試驗(yàn)】 | |
額定電壓 | DC500V,DC1000V |
無負(fù)載電壓 | 額定電壓的1~1.2倍 |
額定測量電流 | 1~1.2mA,短路電流:4~5mA(500V)/2~3mA(1000V) |
測量范圍/精度 | 0.5MΩ~999MΩ(5000V)/1MΩ~999MΩ(1000V):±4%rdg. 1000 MΩ~2000 MΩ:±8%rdg. |
判定方法 | 窗口比較方式(數(shù)字設(shè)定) |
【定時(shí)器】*實(shí)際試驗(yàn)時(shí)會因?yàn)樨?fù)載的不同而導(dǎo)致定時(shí)器設(shè)定時(shí)間的不同 | |
設(shè)置范圍 | 0.3 ~ 999s |
Ramp/Delay | 測試電壓Ramp up、down,絕緣電阻試驗(yàn)延遲:0.1~99.9s |
功能 | 耐壓,在絕緣電阻的試驗(yàn)內(nèi)容中各8種內(nèi)存,保持,蜂鳴器,檢查接觸功能(耐壓,絕緣抵抗) |
監(jiān)測功能 | 輸出電壓,檢測電流,絕緣電阻。監(jiān)測周期:4回/s以上 |
電源 | AC100~240V(50/60Hz),最大200VA |
體積/重量 | 320W×155H×395Dmm,15kg |
附件 | 9615高壓測試線(高壓線和回路,各1),電源線×1,使用說明書×1,防脫落擋板×1 |
自動絕緣耐壓測試儀
測量參數(shù)耐壓:CS2676A 0-5kV/20mA(AC) CS2676B 0-5kV/100mA(AC) 絕緣:測試電阻:0.5-20000MΩ 測試電壓:500/1000V 測量精度:±5% 測試時(shí)間:1-60s 手控時(shí)間:∞
CS2676D 自動絕緣耐壓測試儀性能指標(biāo):
·具有雙定時(shí)功能 ·可任意選擇測試模式(I、W、I-W、W-I) ·漏電流、測試時(shí)間可連續(xù)設(shè)定·高壓擊穿保護(hù)·越限聲光報(bào)警·可選配遙控測試槍【測量參數(shù)】耐壓:0-5kV/100mA(AC)絕緣:測試電阻:0.5-20000MΩ 測試電壓:500/1000V測量精度:±5%測試時(shí)間:1-60s手控時(shí)間:∞
GY-2676型自動絕緣耐壓測試儀 QQ1946210180
1、 測試參數(shù)連續(xù)設(shè)定。
2、四種測試模式(W、I、W-I、I-W)任意設(shè)定。
3.不合格聲光報(bào)警,高壓擊穿保護(hù)。
4.手動、遙控測試,指針式雙表顯示。
5、測試電壓:AC 0~1.5~5kV ±3%。
6、漏電流范圍:AC 0~2~20mA。
7、絕緣電阻范圍:0.2~2000MΩ(500/1000V)
8、電阻精度:±5%。
9、變壓器容量:750VA。
GY2676型自動絕緣耐壓測試儀測試參數(shù)連續(xù)設(shè)定。 四種測試模式(W、I、W-I、I-W)任意設(shè)定。 不合格聲光報(bào)警,高壓擊穿保護(hù)。手動、遙控測試,指針式雙表顯示。測試電壓:AC 0~1.5~5kV ±3%。 漏電流范圍:AC 0~2~20mA。絕緣電阻范圍:0.2~2000MΩ(500/1000V)電阻精度:±5%?!臼酆蟆糠?wù)保障:1、簽訂產(chǎn)品質(zhì)量保障書,承諾-不合格產(chǎn)品絕不出廠。2、兩年內(nèi)產(chǎn)品質(zhì)量跟蹤服務(wù),并將客戶服務(wù)記錄在檔案保存20年。3、確因產(chǎn)品質(zhì)量問題,我公司將保修、包退、包換、滿足客戶要求。生產(chǎn)廠家:中諾試驗(yàn)設(shè)備儀器有限公司地址:東莞市萬江區(qū)流涌尾汾溪路第一工業(yè)區(qū)
型號:RL134261耐壓絕緣測試儀 LK7110 | 型號:RL134262交流耐壓絕緣測試儀 LW-7112 | 型號:RL134263交直流絕緣耐壓測試儀 |
程控耐壓絕緣測試儀系列 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
1、超小體積,重量輕
2、操作簡單,鍵盤鎖定功能
3、提供5組記憶體設(shè)定,每組可選四種工作摸式
4、LCD液晶顯示,測試狀態(tài)、結(jié)果一目了然
5、電壓按時(shí)間梯度上升,實(shí)時(shí)分析、尋找擊穿點(diǎn)
6、電流上下限設(shè)置,智能報(bào)警
7、電弧偵測功能(1-9級)
8、提供遠(yuǎn)程PLC控制接口
技術(shù)參數(shù) | 范 圍 | 解析度 | 基本精度 |
交流耐壓特性(所有型號基本功能) | |||
輸 出 電 壓 | 0 – 5.00(KVac)/ 12(mA) | 0.01 | ±(2% of setting +5V) |
輸出頻率波形 | 50 or 60 Hz,±100ppm,正弦波,失真度(THD)< 2% | ||
電流上下限設(shè)定 | 0.10 – 12.00(mA) | 0.01 | ±(2% of setting +2 counts) |
上升時(shí)間,秒(s) | 0.1 – 999.9 (s) | 0.1 | ±(0.1% +0.05 counts ) |
測試時(shí)間,秒(s) | 0, 0.2 – 999.9 (s) (0 =連續(xù)) | 0.1 | ±(0.1% +0.05 counts) |
電弧(Arc)偵測 | 9級(0為關(guān)閉,1為靈敏) | ||
直流耐壓特性(僅7120,7122有此功能) | |||
輸 出 電 壓 | 0 – 6.00(KVdc)/ 5 (mA) | 0.01 | ±(2% of setting +5V) |
電 流 設(shè) 定 | 0.02 -- 5.00(mA) | 0.01 | ±(2% of setting +2 counts) |
上升時(shí)間,秒(s) | 0.1 – 999.9 (s) | 0.1 | ±(0.1% +0.05 counts) |
測試時(shí)間,秒(s) | 0, 0.2 – 999.9 (s) (0 =連續(xù)) | 0.1 | ±(0.1% +0.05 counts) |
電弧(Arc)偵測 | 9級(0為關(guān)閉,1為靈敏) | ||
絕緣電阻特性(僅7112,7122有此功能) | |||
輸 出 電 壓 | 0.10 – 1.00(KVdc) | 0.01 | ±(2% of setting +5V) |
絕緣電阻上限 | 0 – 2000 (MΩ)(0=關(guān)閉) | 1 | ±(2% of setting+2c.)≥500vdc |
絕緣電阻下限 | 1 – 2000 (MΩ) | 1 | ±(5% of setting+2c.)<500vdc |
測試時(shí)間,秒(s) | 0, 0.5 – 999.9 (s) (0 =連續(xù)) | 0.1 | ±(0.1% +0.05 counts ) |
其他規(guī)格 | |||
記憶組(Memory) | 5組記憶, 4種測試模式:W,I,W – I,I -- W | ||
外設(shè)遙控、PLC接口 | 提供Pass、Fail、Processing遙控監(jiān)視信號和TEST、STOP接點(diǎn) | ||
安全保護(hù) | 過載或短路自動切斷輸出,信號燈和蜂鳴報(bào)警 | ||
整機(jī)尺寸 | 280mm(W)×89mm(H)×320mm(D) / 10Kg |
欄目頁面:http://www.runlian365.com/chanpin/9478.html耐壓絕緣測試儀來源網(wǎng)址:http://www.runlian365.com/chanpin/did-134262-pid-9478.html交流耐壓絕緣測試儀 LW-7112型號:RL134263交直流絕緣耐壓測試儀
技 術(shù) 參 數(shù) | 范 圍 | 解析度 | 基 本 精 度 |
交流耐壓特性(所有型號基本功能) | |||
輸 出 電 壓 | 0 – 5.00(KVac)/ 12(mA) | 0.01 | ±(2% of setting +5V) |
輸出頻率波形 | 50 or 60 Hz, ±100 ppm, 正弦波, 失真度(THD)< 2% | ||
電流上下限設(shè)定 | 0.10 – 12.00(mA) | 0.01 | ±(2% of setting +2 counts) |
上升時(shí)間,秒(s) | 0.1 – 999.9 (s) | 0.1 | ±(0.1% +0.05 counts ) |
測試時(shí)間,秒(s) | 0, 0.2 – 999.9 (s) (0 = 連續(xù)) | 0.1 | ±(0.1% +0.05 counts) |
電弧(Arc)偵測 | 9級(0 為關(guān)閉,1為靈敏) | ||
直流耐壓特性(僅7120,7122有此功能) | |||
輸 出 電 壓 | 0 – 6.00(KVdc)/ 5 (mA) | 0.01 | ±(2% of setting +5V) |
電 流 設(shè) 定 | 0.02 -- 5.00(mA) | 0.01 | ±(2% of setting +2 counts) |
上升時(shí)間,秒(s) | 0.1 – 999.9 (s) | 0.1 | ±(0.1% +0.05 counts) |
測試時(shí)間,秒(s) | 0, 0.2 – 999.9 (s) (0 = 連續(xù)) | 0.1 | ±(0.1% +0.05 counts) |
電弧(Arc)偵測 | 9級(0 為關(guān)閉,1為靈敏) | ||
絕緣電阻特性(僅7112,7122有此功能) | |||
輸 出 電 壓 | 0.10 – 1.00(KVdc) | 0.01 | ±(2% of setting +5V) |
絕緣電阻上限 | 0 – 2000 (MΩ) (0=關(guān)閉) | 1 | ±(2% of setting+2c.) ≥500vdc ±(5% of setting+2c.) < 500vdc |
絕緣電阻下限 | 1 – 2000 (MΩ) | 1 | |
測試時(shí)間,秒(s) | 0, 0.5 – 999.9 (s) (0 = 連續(xù)) | 0.1 | ±(0.1% +0.05 counts ) |
其他規(guī)格 | |||
記憶組(Memory) | 5組記憶, 4種測試模式: W,I,W – I,I -- W | ||
外設(shè)遙控、PLC接口 | 提供Pass、Fail、Processing遙控監(jiān)視信號和TEST、STOP接點(diǎn) | ||
安全保護(hù) | 過載或短路自動切斷輸出, 信號燈和蜂鳴報(bào)警 | ||
整機(jī)尺寸 | 280mm(W) × 89mm(H) × 320mm(D) / 10Kg |
詳細(xì)介紹 | |
絕緣電阻測試(DC50V~1200V),耐壓測試(AC/DC5000V),全遠(yuǎn)程控制 可編程測試(測試程序32個(gè)文件,測試點(diǎn)每個(gè)文件50步) 通過PWM控制方法,產(chǎn)生精確的測試電壓 3930高電壓掃描單元(選件) | |
功能描述 |
測量功能 | 耐壓測試 |
測試電壓 | 0~2.5kV/0~5.0kV AC,二波段構(gòu)成 |
電壓外加方式 | 零點(diǎn)開關(guān) |
變壓器容量 | 500VA(最大30分鐘) |
電壓調(diào)校 | 手動調(diào)校變壓器 |
波形 | 同電源波形 |
頻率 | 同電源頻率 |
測量項(xiàng)目 | 電壓:交流0~5kV(調(diào)整平均值,值顯示) 電流:交流0.01~120mA(調(diào)整平均值,值顯示) |
判斷功能 | 內(nèi)容:超高限-失敗/通過/超低限-失敗 (數(shù)字設(shè)置窗口比較方法) |
定時(shí)功能 | 設(shè)置范圍:0.5~999秒 |
接口 | EXT I/O, EXT SW, RS-232C |
顯示 | 熒光管顯示(數(shù)字),模擬指針 |
監(jiān)測功能 | 輸出電壓,探測電流 |
電源供應(yīng) | 120V AC,50/60Hz,(3158-01) 220V AC,50/60Hz,(3158-03) 230V AC,50/60Hz,(3158-04) 240V AC,50/60Hz,(3158-05) |
外部特征 | |
體積及重量 | 320寬×155高×263厚mm,16kg(3158-01) 18kg(3158-03,04,05) |
附件與選件 | |
附件 | 9615高壓測試線(高壓側(cè)和回路各1),電源線(1),備用保險(xiǎn)絲(1) |
選件 | 遠(yuǎn)程控制箱或測試線 3930 高壓掃描器 9613 遠(yuǎn)程控制箱(單) 9614 遠(yuǎn)程控制箱(雙) 9615 高壓測試線 (已包括) PC通訊器 9151-02 GP-IB 電纜 2m長 9151-04 GP-IB 電纜 4m長 9637 電纜 9pin-9pin,1.8m長 9638 電纜 9pin-25pin,1.8m長 |
1、 測試參數(shù)連續(xù)設(shè)定。 2、四種測試模式(W、I、W-I、I-W)任意設(shè)定。 3.不合格聲光報(bào)警,高壓擊穿保護(hù)。4.手動、遙控測試,指針式雙表顯示。5、測試電壓:AC 0~1.5~5kV ±3%。 6、漏電流范圍:AC 0~2~20mA。7、絕緣電阻范圍:0.2~2000MΩ(500/1000V)8、電阻精度:±5%。