亚洲视频福利,日本精品一区二区三区在线,日韩欧美在线视频一区二区,国产高清自产拍av在线,99久久99久久精品国产片果冻,国产视频手机在线,成人禁在线观看午夜亚洲

MP系列旺泉MP系列微型磁力泵(磁力驅(qū)動(dòng)循環(huán)泵)

旺泉MP系列微型磁力泵(磁力驅(qū)動(dòng)循環(huán)泵)特點(diǎn):
本公司生產(chǎn)該產(chǎn)品歷史,有極小型至大型等多種型號(hào),其外形及工作性能同日本的易威奇(IWAKI)相媲美.選擇流量范圍由每分鐘1公升至120公升,多種不同材質(zhì),可以用來(lái)輸送多種腐蝕性的液體。MP系列因其結(jié)構(gòu)小巧,非常適合用作照相沖洗設(shè)備和其它裝置的OEM產(chǎn)品。有軟管、螺紋等連接接口適合各種工業(yè)系統(tǒng)和程序上使用。旺泉泵業(yè)并獲得專利保護(hù)。
最大流量:135L/min
揚(yáng)程:14.3m
主要材質(zhì):GFRPP
功率范圍:3~265W
液溫范圍:0~80℃
絕無(wú)泄漏,結(jié)構(gòu)特殊。本泵可輸送酸、堿、鹽、油品、飲料等介質(zhì),廣泛用于化工、石油化工、精細(xì)化工、染料化工、環(huán)保、水處理、醫(yī)藥、食品等部門(mén)。
磁力驅(qū)動(dòng)循環(huán)泵運(yùn)轉(zhuǎn)是在連軸上和葉輪上分別裝配有磁性材料而互相吸引偶合,無(wú)需配以傳統(tǒng)機(jī)械軸封,因而是密封的。電動(dòng)機(jī)轉(zhuǎn)動(dòng)扭力是通過(guò)主動(dòng)磁及從動(dòng)磁的引力帶動(dòng)葉片工作運(yùn)轉(zhuǎn)?,F(xiàn)今慣用的磁力驅(qū)動(dòng)泵極大的缺點(diǎn)是在缺液情況下絕對(duì)嚴(yán)禁運(yùn)轉(zhuǎn)否則整機(jī)將毀壞,給使用者增添不必要的麻煩和煩惱。"上海旺泉泵業(yè)"的磁力驅(qū)動(dòng)泵則不必為此擔(dān)心。它采選了一種特別設(shè)計(jì)的特配方陶瓷作軸承,具有極強(qiáng)的耐磨性和抗腐蝕性,使其性能和質(zhì)量安全得以絕對(duì)的?! 〈帕︱?qū)動(dòng)循環(huán)泵概用無(wú)軸封設(shè)計(jì),避免了傳統(tǒng)機(jī)械軸封泵存在的液體泄漏引起的腐蝕后污染的缺陷,是工業(yè)設(shè)備上最理想的液體輸送泵。
以來(lái),在生產(chǎn)流程中為流體輸送和化學(xué)反應(yīng)所裝備的泵,均是軸封式的.即轉(zhuǎn)軸的密封采用機(jī)械密封或填料密封。這種轉(zhuǎn)軸密封裝置不可克服的結(jié)構(gòu)缺點(diǎn)就是泄漏,因?yàn)樗仨氁揽枯斔徒橘|(zhì)或工作介質(zhì)的泄漏來(lái)潤(rùn)滑轉(zhuǎn)軸的密封面,而且隨軸封在高速運(yùn)轉(zhuǎn)中的逐漸磨損,其泄漏量也將隨磨損量的增大而增大,特別是對(duì)易燃、易爆、有毒、有害介質(zhì)的泄漏,既對(duì)環(huán)境造成污染,又危及生產(chǎn)安全和操作人員的健康。為杜絕化工生產(chǎn)領(lǐng)域的泄漏,消除環(huán)境污染,保護(hù)生態(tài)環(huán)境,保障生產(chǎn)安全和操作人員的身體健康.上海旺泉泵業(yè)有限公司結(jié)合本公司及國(guó)外技術(shù)與國(guó)內(nèi)的大學(xué)的專業(yè)研究院所共同研制開(kāi)發(fā),成功地推出了旺泉 MP,CQ,CQF,CQB,CQG系列磁力泵無(wú)泄漏化工裝備,為我國(guó)化工裝備的無(wú)泄漏做出了貢獻(xiàn)。

PHB-60PH計(jì)

PH計(jì)

① pH值測(cè)量范圍:0~14.00pH

② mV值測(cè)量范圍:0~±1500mV(自動(dòng)極性顯示)

③ pH值測(cè)量精度:≤0.05pH

④ mV值測(cè)量精度:≤0.5%(讀數(shù))±1個(gè)字

⑤ 輸入阻抗:≥1×1012Ω

⑥ 零點(diǎn)漂移:≤0.03pH/3小時(shí)

特價(jià)6ES7212-1AB23-0XB8特價(jià)西門(mén)子PLC

 

一級(jí)代理西門(mén)子S7-200CN PLC6ES7214-1BD23-0XB8現(xiàn)貨
歡迎來(lái)電訂購(gòu): 陳小姐
竭誠(chéng)為您服務(wù)!充足的庫(kù)存,熱情的服務(wù),實(shí)惠合理的價(jià)格是您的伙伴。您的選擇從我這里開(kāi)始。
 
6ES7212-1AB23-0XB8
6ES7212-1BB23-0XB8
6ES7214-1AD23-0XB8
6ES7214-1BD23-0XB8
6ES7214-2AD23-0XB8
6ES7214-2BD23-0XB8
6ES7216-2AD23-0XB8
6ES7216-2BD23-0XB8
6ES7221-1BF22-0XA8
6ES7221-1BH22-0XA8
6ES7222-1BF22-0XA8
6ES7222-1HF22-0XA8
6ES7223-1BF22-0XA8
6ES7223-1HF22-0XA8
6ES7223-1BH22-0XA8
6ES7223-1PH22-0XA8
6ES7223-1BL22-0XA8
6ES7223-1PL22-0XA8
6ES7231-0HC22-0XA8
6ES7231-7PB22-0XA8
6ES7231-7PD22-0XA8
6ES7232-0HB22-0XA8
6ES7235-0KD22-0XA8
 
6ES7211-0AA21-0XB0
6ES7211-0BA21-0XB0
6ES7212-1AB21-0XB0
6ES7212-1BB21-0XB0
6ES7214-1AD21-0XB0
6ES7214-1BD21-0XB0
6ES7216-2AD21-0XB0
6ES7216-2AF21-0XB0
6ES7216-2BD21-0XB0
6ES7216-2BF21-0XB0
6ES7221-1BF21-0XA0
6ES7221-1EF22-0XA0
6ES7222-1BF21-0XA0
6ES7222-1EF22-0XA0
6ES7222-1HF21-0XA0
6ES7223-1BF21-0XA0
6ES7223-1BH21-0XA0
6ES7223-1BL21-0XB0
6ES7223-1HF21-0XA0
6ES7223-1PH21-0XA0
6ES7223-1PL21-0XA0
6ES7231-0HC21-0XA0
6ES7231-7PB21-0XA0
6ES7231-7PD21-0XA0
6ES7232-0HB21-0XA0
6ES7235-0KD21-0XA0
 
6ES7272-0AA20-0YA0
6ES7274-1XF00-0XA0
6ES7274-1XH00-0XA0
6ES7274-1XK00-0XA0
6ES7277-0AA21-0XA0
更多品牌與型號(hào)歡迎向本人咨詢
該公司產(chǎn)品分類(lèi): 德國(guó)西門(mén)子 PLC放大板 德國(guó)西門(mén)子 7ME流量?jī)x表 德國(guó)西門(mén)子 7NG溫度儀表 德國(guó)西門(mén)子 7ML物位儀表 德國(guó)西門(mén)子 7MF壓力儀表 德國(guó)西門(mén)子 S7-400PLC 德國(guó)西門(mén)子 S7-300PLC 德國(guó)西門(mén)子 S7-200cn PLC 德國(guó)西門(mén)子 S7-200PLC 德國(guó)西門(mén)子 6ED LOGO模塊 德國(guó)西門(mén)子 6EP SITOP工業(yè)電源 德國(guó)西門(mén)子 6GK工業(yè)以太網(wǎng)模塊 德國(guó)西門(mén)子 6DR閥門(mén)定位器 德國(guó)西門(mén)子 6AV觸摸屏 德國(guó)西門(mén)子 7MH稱重傳感器 德國(guó)西門(mén)子 7MH稱重模塊

BIOSH大鼠AP核酸內(nèi)切酶-1(APE1)酶聯(lián)免疫分析(ELISA)

 

大鼠AP核酸內(nèi)切酶-1APE1)酶聯(lián)免疫分析(ELISA)

試劑盒使用說(shuō)明書(shū)

本試劑僅供研究使用      目的:本試劑盒用于測(cè)定大鼠血清、血漿、組織勻漿及相關(guān)液體樣本中AP核酸內(nèi)切酶-1APE1)的含量。

 

實(shí)驗(yàn)原理:

本試劑盒應(yīng)用雙抗體夾心法測(cè)定標(biāo)本中大鼠AP核酸內(nèi)切酶-1APE1水平。用純化的大鼠AP核酸內(nèi)切酶-1APE1)捕獲抗體包被微孔板,制成固相抗體,往包被的微孔中依次加入大鼠AP核酸內(nèi)切酶-1APE1,再與HRP標(biāo)記的檢測(cè)抗體結(jié)合,形成抗體-抗原-酶標(biāo)抗體復(fù)合物,經(jīng)過(guò)徹底洗滌后加底物TMB顯色。TMBHRP酶的催化下轉(zhuǎn)化成藍(lán)色,并在酸的作用下轉(zhuǎn)化成最終的黃色。顏色的深淺和樣品中的大鼠AP核酸內(nèi)切酶-1APE1呈正相關(guān)。用酶標(biāo)儀在450nm波長(zhǎng)下測(cè)定吸光度(OD值),通過(guò)標(biāo)準(zhǔn)曲線計(jì)算樣品中大鼠AP核酸內(nèi)切酶-1APE1含量。

 

試劑盒組成

試劑盒組成

48孔配置

96孔配置

保存

說(shuō)明書(shū)

1

1

 

封板膜

2

2

 

密封袋

1個(gè)

1個(gè)

 

酶標(biāo)包被板

1×48

1×96

2-8保存

標(biāo)準(zhǔn)品

0.3ml×6

0.3ml×6

2-8保存

酶標(biāo)試劑

5 ml×1

10 ml×1

2-8保存

樣品稀釋液

3 ml×1

6 ml×1

2-8保存

顯色劑A

3 ml×1

6 ml×1

2-8保存

顯色劑B

3 ml×1

6 ml×1

2-8保存

終止液

3 ml×1

6 ml×1

2-8保存

20×濃縮洗滌液

15ml×1

25ml×1

2-8保存

注:標(biāo)準(zhǔn)品濃度依次為:16、8、4、21、0 ng/mL.

 

樣本處理及要求

1. 血清:室溫血液自然凝固10-20分鐘,離心20分鐘左右(2000-3000轉(zhuǎn)/分)。仔細(xì)收集上清,保存過(guò)程中如出現(xiàn)沉淀,應(yīng)再次離心。

2. 血漿:應(yīng)根據(jù)標(biāo)本的要求選擇EDTA或檸檬酸鈉作為抗凝劑,混合10-20分鐘后,離心20分鐘左右(2000-3000轉(zhuǎn)/分)。仔細(xì)收集上清,保存過(guò)程中如有沉淀形成,應(yīng)該再次離心。

3. 尿液:用無(wú)菌管收集,離心20分鐘左右(2000-3000轉(zhuǎn)/分)。仔細(xì)收集上清,保存過(guò)程中如有沉淀形成,應(yīng)再次離心。胸腹水、腦脊液參照實(shí)行。

4. 細(xì)胞培養(yǎng)上清:檢測(cè)分泌性的成份時(shí),用無(wú)菌管收集。離心20分鐘左右(2000-3000轉(zhuǎn)/分)。仔細(xì)收集上清。檢測(cè)細(xì)胞內(nèi)的成份時(shí),用PBSPH7.2-7.4)稀釋細(xì)胞懸液,細(xì)胞濃度達(dá)到100萬(wàn)/ml左右。通過(guò)反復(fù)凍融,以使細(xì)胞破壞并放出細(xì)胞內(nèi)成份。離心20分鐘左右(2000-3000轉(zhuǎn)/分)。仔細(xì)收集上清。保存過(guò)程中如有沉淀形成,應(yīng)再次離心。

5. 組織標(biāo)本:切割標(biāo)本后,稱取重量。加入一定量的PBS,PH7.4。用液氮迅速冷凍保存?zhèn)溆?。?biāo)本融化后仍然保持2-8的溫度。加入一定量的PBSPH7.4),用手工或勻漿器將標(biāo)本勻漿充分。離心20分鐘左右(2000-3000轉(zhuǎn)/分)。仔細(xì)收集上清。分裝后一份待檢測(cè),其余冷凍備用。

6. 標(biāo)本采集后盡早進(jìn)行提取,提取按相關(guān)文獻(xiàn)進(jìn)行,提取后應(yīng)盡快進(jìn)行實(shí)驗(yàn)。若不能馬上進(jìn)行試驗(yàn),可將標(biāo)本放于-20保存,但應(yīng)避免反復(fù)凍融.

7. 不能檢測(cè)含NaN3的樣品,因NaN3抑制辣根過(guò)氧化物酶的(HRP)活性。

 

操作步驟

1.   標(biāo)準(zhǔn)品的加樣:設(shè)置標(biāo)準(zhǔn)品孔和樣本孔,標(biāo)準(zhǔn)品孔各加不同濃度的標(biāo)準(zhǔn)品50μL;。

2.   加樣:分別設(shè)空白孔(空白對(duì)照孔不加樣品及酶標(biāo)試劑,其余各步操作相同)、待測(cè)樣品孔。在酶標(biāo)包被板上待測(cè)樣品孔中先加樣品稀釋液40μl,然后再加待測(cè)樣品10μl(樣品最終稀釋度為5倍)。加樣將樣品加于酶標(biāo)板孔底部,盡量不觸及孔壁,輕輕晃動(dòng)混勻。

3.   加酶:每孔加入酶標(biāo)試劑100μl,空白孔除外。

4.   溫育:用封板膜封板后置37溫育60分鐘。

5.   配液:將20倍濃縮洗滌液用蒸餾水20倍稀釋后備用。

6.   洗滌:小心揭掉封板膜,棄去液體,甩干,每孔加滿洗滌液,靜置30秒后棄去,如此重復(fù)5次,拍干。

7.   顯色:每孔先加入顯色劑A50μl,再加入顯色劑B50μl,輕輕震蕩混勻,37避光顯色15分鐘.

8.   終止:每孔加終止液50μl,終止反應(yīng)(此時(shí)藍(lán)色立轉(zhuǎn)黃色)。

9.   測(cè)定:以空白孔調(diào)零,450nm波長(zhǎng)依序測(cè)量各孔的吸光度(OD值)。 測(cè)定應(yīng)在加終止液后15分鐘以內(nèi)進(jìn)行。

 

注意事項(xiàng):

1. 試劑盒從冷藏環(huán)境中取出應(yīng)在室溫平衡15-30分鐘后方可使用,酶標(biāo)包被板開(kāi)封后如未用完,板條應(yīng)裝入密封袋中保存。

2. 濃洗滌液可能會(huì)有結(jié)晶析出,稀釋時(shí)可在水浴中加溫助溶,洗滌時(shí)不影響結(jié)果。

3. 各步加樣均應(yīng)使用加樣器,并經(jīng)常校對(duì)其準(zhǔn)確性,以避免試驗(yàn)誤差。一次加樣時(shí)間最好控制在5分鐘內(nèi),如標(biāo)本數(shù)量多,推薦使用排槍加樣。

4. 請(qǐng)每次測(cè)定的同時(shí)做標(biāo)準(zhǔn)曲線,最好做復(fù)孔。如標(biāo)本中待測(cè)物質(zhì)含量過(guò)高(樣本OD值大于標(biāo)準(zhǔn)品孔第一孔的OD值),請(qǐng)先用樣品稀釋液稀釋一定倍數(shù)(n倍)后再測(cè)定,計(jì)算時(shí)請(qǐng)最后乘以總稀釋倍數(shù)(×n×5)。

5. 封板膜只限一次性使用,以避免交叉污染。

6. 底物請(qǐng)避光保存。

7. 嚴(yán)格按照說(shuō)明書(shū)的操作進(jìn)行,試驗(yàn)結(jié)果判定必須以酶標(biāo)儀讀數(shù)為準(zhǔn).

8. 所有樣品,洗滌液和各種廢棄物都應(yīng)按傳染物處理。

9. 本試劑不同批號(hào)組分不得混用。

10. 如與英文說(shuō)明書(shū)有異,以英文說(shuō)明書(shū)為準(zhǔn)。

 

 

 

計(jì)算:

以標(biāo)準(zhǔn)物的濃度為橫坐標(biāo),OD值為縱坐標(biāo),   

在坐標(biāo)紙上繪出標(biāo)準(zhǔn)曲線,根據(jù)樣品的OD     

值由標(biāo)準(zhǔn)曲線查出相應(yīng)的濃度;再乘以稀釋      

倍數(shù);或用標(biāo)準(zhǔn)物的濃度與OD值計(jì)算出標(biāo)      

準(zhǔn)曲線的直線回歸方程式,將樣品的OD      

代入方程式,計(jì)算出樣品濃度,再乘以稀釋      

倍數(shù),即為樣品的實(shí)際濃度。                  

 

                                             

 

(此圖僅供參考)

 

 

 

試劑盒性能:

1.樣品線性回歸與預(yù)期濃度相關(guān)系數(shù)R值為0.95以上。

2.批內(nèi)變異系數(shù)與批間變異系數(shù)應(yīng)分別小于10%15% 。

 

檢測(cè)范圍:                                              

0.5 ng/mL - 16 ng/mL

 

靈敏度:                                             

最低檢測(cè)濃度小于0.1 ng/mL

 

保存條件及有效期:

1.試劑盒保存: 2-8

2.有效期: 6個(gè)月

Rat apurinic;apyrimidinic endonuclease 1

FOR RESEARCH USE ONLY

 

Drug Names

Generic NameRat apurinic;apyrimidinic endonuclease 1 (APE1) ELISA Kit.

Purpose

This kit allows for the determination of APE1 concentrations in Rat serum, plasma, tissue homogenates and other biological fluids.

Principle of the assay

The kit assay Rat APE1 level in the sample, use Purified Rat APE1 antibody to coat microtiter plate wells, make solid-phase antibody, then add APE1 to the wells, Combined antibody which With HRP labeled, become antibody-antigen-enzyme-antibody complex, after washing Completely, Add TMB substrate solution,TMB substrate becomes blue color At HRP enzyme-catalyzed, reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm. The concentration of APE1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.

Materials provided with the kit

Materials provided with the kit

48determinations

96 determinations

Storage

User manual

1

1

 

Closure plate membrane

2

2

 

Sealed bags

1

1

 

Microelisa stripplate

1

1

2-8

Standard

0.3ml×6 bottle

0.3ml×6 bottle

2-8

HRP-Conjugate reagent

5ml×1 bottle

10ml×1 bottle

2-8

Sample diluent

3ml×1 bottle

6ml×1 bottle

2-8

Chromogen Solution A

3ml×1 bottle

6ml×1 bottle

2-8

Chromogen Solution B

3ml×1 bottle

6ml×1 bottle

2-8

Stop Solution

3ml×1 bottle

6ml×1 bottle

2-8

20×Wash solution

15ml×1 bottle

25ml×1 bottle

2-8

Note: Standard concentration was followed by:

16、8、4、21、0 ng/mL.

Specimen requirements

1. serum- coagulation at room temperature 10-20 mins,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

2. plasma-use suited EDTA or citrate plasma as an anticoagulant,mix 10-20 mins ,centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

3. Urine-collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again. The Operation of Hydrothorax and cerebrospinal fluid Reference to it.

4. cell culture supernatant-detect secretory components, collect sue a sterile container, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant,detect the composition of cells, Dilut cell suspension with PBSPH7.2-7.4, Cell concentration reached 1 million / ml, repeated freeze-thaw cycles, damage cells and release of intracellular components, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant, If precipitation appeared, Centrifugal again.

5. Tissue samples- After cutting samples, check the weight,add PBSPH7.2-7.4, Rapidly frozen with liquid nitrogen, maintain samples at 2-8 after melting,add PBSPH7.4, Homogenized by hand or Grinders, centrifugation 20-min at the speed of 2000-3000 r.p.m. remove supernatant.

6. extract as soon as possible after Specimen collection,and according to the relevant literature, and should be experiment as soon as possible after the extraction. If it can’t, specimen can be kept in -20 to preserve, Avoid repeated freeze-thaw cycles.

7. Can’t detect the sample which contain NaN3, because NaN3 inhibits HRP active.

Assay procedure

1. Add standard: Set Standard wells, testing sample wells. Add standard 50μl to standard well.

2.add sampleSet blank wells separately (blank comparison wells don’t add sample and HRP-Conjugate reagent, other each step operation is same). testing sample well. add Sample dilution 40μl to testing sample well, then add testing sample 10μl (sample final dilution is 5-fold), add sample to wells , don’t touch the well wall as far as possible, and Gently mix.

3.add enzymeAdd HRP-Conjugate reagent 100μl to each well, except  blank well.

4.Incubate: After closing plate with Closure plate membrane ,incubate for 60 min at 37.

5.Configurate liquid: 20-fold wash solution diluted 20-fold with distilled water and reserve.

6.washingUncover Closure plate membrane, discard Liquid, dry by swing, add washing buffer to every well, still for 30s then drain, repeat 5 times, dry by pat.

7.colorAdd Chromogen Solution A 50ul and Chromogen Solution B to each well, evade the light preservation for 15 min at 37

8.Stop the reactionAdd Stop Solution 50μl to each well, Stop the reaction(the blue color change to yellow color).

9.assaytake blank well as zero , Read absorbance at 450nm after Adding Stop Solution and within 15min.

Important notes

1. The kit takes out from the refrigeration environment should be balanced 15-30 minutes in the room temperature, ELISA plates coated if has not use up after opened, the plate should be stored in Sealed bag.

2. washing buffer will Crystallization separation, it can be heated the water helps dissolve when dilute . Washing does not affect the result.

3. add Sample with sampler Each step, And proofread its accuracy frequently, avoids the experimental error. add sample within 5 mins, if the number of sample is much , recommend to use Volley .

4. if the testing material content is excessively higher (The sample OD is bigger than the first standard well ),please dilute Sample (n-fold), Please diluente and multiplied by the dilution factor.×n×5.

5. Closure plate membrane only limits the disposable use, to avoid cross-contamination.

6. The substrate evade the light preservation.

7. Please according to use instruction strictly, The test result determination must take the microtiter plate reader as a standard.

8. All samples, washing buffer and each kind of reject should according to infective material process.

9. Do not mix reagents with those from other lots.

 

Take the standard density as the horizontal, the OD value for the vertical ,draw the standard curve on graph paper, Find out the corresponding density according to the sample OD value by the Sample curve, multiplied by the dilution multiple, or calculate the straight line regression equation of the standard curve with the standard density and the OD value ,with the sample OD value in the equation, calculate the sample density, multiplied by the dilution factor, the result is the sample actual density.

 

 

Calculate

 

 
 

This chartis for reference only

 

 

 

 

 

 

 

 

 

 

 

 

Assay range

0.5 ng/mL - 16 ng/mL

 

Sensitivity

The minimum detectable dose is typically less than 0.1 ng/mL

 

Storage and validity

1Storage 2-8.

2validity six months.

該公司產(chǎn)品分類(lèi): ELISA試劑盒

9600原子發(fā)射光譜儀 電感耦合等離子體發(fā)射ICP光譜儀 雜質(zhì)測(cè)試ICP光譜儀

詳細(xì)說(shuō)明:

一、 應(yīng)用范圍(可分析周期表中所有金屬元素和部分非金屬元素)

1.鋼鐵及其合金的分析:包括碳素鋼、鑄鐵、合金鋼、高純鐵、鐵合金等。
2.有色金屬及其合金的分析:包括有色金屬及其合金、稀有金屬及其合金、貴金屬、稀土元素及其化合物。
3.水質(zhì)樣品的分析:包括飲用水、地表水、礦泉水、高純水及廢水等。
4.環(huán)境樣品的分析:包括固體廢物、土壤、粉煤灰、大氣飄塵等。
5.地礦樣品的分析:包括地質(zhì)樣品、礦石及礦物等。
6.動(dòng)植物及生化樣品的分析:包括植物、中藥及動(dòng)物組織、生物化學(xué)樣品等。
7.核工業(yè)產(chǎn)品的分析:包括核燃料、核材料等。
8.食品及飲料的分析:包括食品、飲料等。
9.化學(xué)化工產(chǎn)品的分析:包括化學(xué)試劑化工產(chǎn)品無(wú)機(jī)材料化妝品油類(lèi)等。
二、主要技術(shù)參數(shù)
射頻發(fā)生器(RF)(1) 電路類(lèi)型:電感反饋式自激振蕩電路,全自動(dòng)點(diǎn)火,全自動(dòng)化控制,所有功能實(shí)現(xiàn)電腦設(shè)置(點(diǎn)火、熄火、功率等參數(shù)設(shè)置);實(shí)時(shí)功率控制;自動(dòng)匹配調(diào)諧;光室恒溫;自動(dòng)峰位校正;蠕動(dòng)泵進(jìn)樣,泵速連續(xù)可調(diào);針對(duì)不同樣品有多種進(jìn)樣系統(tǒng)可以選擇(普通進(jìn)樣系統(tǒng)、耐高鹽進(jìn)樣系統(tǒng)、耐氫氟酸進(jìn)樣系統(tǒng));防紫外線輻射、防高頻輻射觀察玻璃,使操作更安全。
同軸電纜輸出,匹配調(diào)諧,取功率反饋,進(jìn)行閉環(huán)自動(dòng)控制。(2) 工作頻率:40.68MHZ±0.05% (3) 頻率穩(wěn)定性:<0.1% (4) 輸出功率:800-1200w (5) 輸出功率穩(wěn)定性:≤0.3% (6) 電磁場(chǎng)泄漏射強(qiáng)度:距機(jī)身30cm 電場(chǎng)強(qiáng)度E:<2V/m,磁場(chǎng)強(qiáng)度H:<0.2A 進(jìn)樣裝置:(1) 輸出工作線圈內(nèi)徑25mm,3匝 (2) 炬管:三同心Fassel型,外徑20mm的石英炬管 (3) 同軸型噴霧器外徑6mm (4) 雙筒形霧室外徑35mm (5) 氬氣流計(jì)規(guī)格和載氣壓力表規(guī)格: ①、 等離子體流量計(jì)(100-1000)L/h ;(1.6-16L/min) ②、 輔助氣流量計(jì)(10-100)L/h ;(0.16-1.66L/min) ③、 載氣流量計(jì)(10-100)L/h ;(0.16-1.66L/min) ④、 載氣穩(wěn)壓閥(0-0.4MPa)
測(cè)光裝置:(1) 光電倍增管規(guī)格: R212UH (2) 光電倍增管負(fù)高壓:200-1000V ,穩(wěn)定性<0.05% (3) 光電倍增管電流測(cè)量范圍:10-12 -10-4A (4) 信號(hào)采集為V/F交換:1mV對(duì)應(yīng)100Hz
分光器:(1) 光路: Czerny- Turner (2) 焦距: 1000mm (3) 光柵規(guī)格:離子刻蝕全息光柵,刻線密度3600線/mm,
刻線面積: 80×110mm,線色散率倒數(shù):0.26nm (4) 波長(zhǎng)范圍:190-500nm (5) 分辨率: ≤0.008nm (6) 掃描波長(zhǎng)范圍3600線/mm 掃描波長(zhǎng)范圍:190-500nm(7) 步進(jìn)電機(jī)驅(qū)動(dòng)小步距:0.0005nm (8) 入射狹縫:20µm 出射狹縫:25µm(9) 發(fā)射鏡規(guī)格:(78 × 105 × 16)mm (10) 透鏡ф30,1:1成像
三、檢測(cè)元素及其檢出限:
四、產(chǎn)品特點(diǎn)
1.分析速度快 一分鐘快分析15個(gè)元素以上
2.精密度高 相對(duì)標(biāo)準(zhǔn)偏差RSD≤1.5%
3.穩(wěn)定性好 相對(duì)標(biāo)準(zhǔn)偏差RSD≤2.0%
4.檢出限低 μg∕L
5.分析元素多 可對(duì)70多種元素進(jìn)行定量分析
6.操作便捷 Windows運(yùn)行環(huán)境功能齊全
7.全自動(dòng)點(diǎn)火 氣路智能控制,實(shí)現(xiàn)軟件點(diǎn)火,更方便
8.安全 有冷卻水保護(hù)、氬氣保護(hù)、滅弧保護(hù)更安全
采用多重屏蔽和良好的接地,使儀器輻射小于2V/m (JJG768-2005規(guī)定小于
10V/m)。更好地操作者的安全。
該公司產(chǎn)品分類(lèi): 水質(zhì)分析儀/多參數(shù)水質(zhì)分析儀 光譜儀 ICP光譜儀

美國(guó) KEP ,批量控制器,計(jì)數(shù)器,隔離器等現(xiàn)場(chǎng)儀表

KEP公司是世界上的現(xiàn)場(chǎng)儀表制造公司,主要生產(chǎn)流量產(chǎn)品、信號(hào)轉(zhuǎn)換器、過(guò)程控制器、指示器、計(jì)數(shù)器、流量計(jì)算機(jī)、批量控制器等,也涉及自動(dòng)控制系統(tǒng)。其產(chǎn)品經(jīng)濟(jì)耐用,操作方便簡(jiǎn)單。廣泛應(yīng)用于石油、化工、電力、冶金、制藥、造紙、食品等行業(yè)。  

系列如下:AH57,AHK07,AK,AMB,AMK,AMP,AW,B15,B16,B18,BA8ANA,BA8IO7,BAT,BC,BCA,BCR,BT2,CH,CTF,DPF,E,ETM,FLO,H37,H57,HB17,HC77,HK07,INT6*,KAL,KE,L,MASS,ML,MM,MT,PC,ST,PD,TR,W15,W16,ZOIDDA,ZOIDDB,ZOIDDC,XHV等等

CA-21P,CA-41P,CA-51P,CA-61PCA-21P,CA-41P琦勝,conch計(jì)米器

功能說(shuō)明 :顯示範(fàn)圍:2~ 6 位數(shù)設(shè)定範(fàn)圍:1~999999字型尺寸:0.56"LED 2或4位數(shù)      0.4" LED 5或6位數(shù) 計(jì)數(shù)輸入:有接點(diǎn)輸入:25HZ     無(wú)接點(diǎn)輸入:3KHZ輸出方式:1 Relay output(1a,b AC 250OV/5A),0.1~5 seconds復(fù)歸方式:外部手動(dòng)&自動(dòng)復(fù)歸輸入信號(hào):NPN open collector (或PNP輸入)電源電壓:AC 110V/ 220V ±15% 50HZ / 60HZ信號(hào)電源:DC12V±5 MAX消耗電力:3.3VA耐溫溫度:-10℃ ~ + 50℃ 35% ~ 85%RH尺寸規(guī)格:72mm × 72mm × 145mm (盤(pán)面開(kāi)孔:68mm×68mm)

該公司產(chǎn)品分類(lèi): 直流調(diào)速器 直流電機(jī) NEMICON 變頻器 APB SR FAB 亞銳控制器 琦勝 紅獅

iCAP Q等離子體質(zhì)譜ICP-MS

iCAP Q等離子體質(zhì)譜ICP-MS產(chǎn)品簡(jiǎn)介
賽默飛iCAP™ Q源于用戶靈感設(shè)計(jì),采用了全新的先進(jìn)工藝和突破性的技術(shù),是ICP-MS發(fā)展過(guò)程中的革命性進(jìn)步。iCAP™ Q比其它任何系統(tǒng)都更易使用、更易維護(hù),而且具備更強(qiáng)的分析能力。無(wú)論您進(jìn)行常規(guī)分析還是前沿研究,均可為您提供值得信賴的分析結(jié)果。
iCAP Q等離子體質(zhì)譜ICP-MS產(chǎn)品特點(diǎn)
- 出色的可靠性
iCAP™ Q采用自準(zhǔn)直中心管、錐和透鏡組件,無(wú)可匹敵的等離子體和碰撞池穩(wěn)定性,改善了復(fù)雜樣品基體耐受性。很少的維護(hù)即可獲得準(zhǔn)確的結(jié)果 - 甚至是對(duì)于具有挑戰(zhàn)性的復(fù)雜樣品也是如此。一鍵儀器設(shè)置和直觀分析工作流程避免了用戶出錯(cuò),并確保了操作的一致性和結(jié)果的重現(xiàn)性。
- 高性能
Thermo Scientific專利的Qcell池,采用先進(jìn)的Flatapole技術(shù)、結(jié)合業(yè)已驗(yàn)證的氦KED(動(dòng)能歧視效應(yīng))干擾消除與獨(dú)特的低質(zhì)量數(shù)剔除功能,來(lái)保證碰撞次模式分析的可靠性??稍谌|(zhì)譜范圍內(nèi)采用單氦KED模式,即便是低質(zhì)量元素(如鋰、鈹和硼)也可獲得ppt級(jí)的檢測(cè)限。
- 令人難以置信的靈活性
工作臺(tái)高度、進(jìn)樣區(qū)域的開(kāi)放性使得外圍設(shè)備的連接比以往任何時(shí)候都更容易。最短的樣品進(jìn)樣通路,使所有附件的分析效率得以提高。減小了峰展寬效應(yīng)。
- 進(jìn)樣系統(tǒng)
工作臺(tái)高度的進(jìn)樣位置,使用戶可以快速、方便的操作,iCAP™ Q的進(jìn)樣系統(tǒng)包括高效、低流量同心霧化器,搭配小型 Peltier 冷卻漩流霧化室,可提供最佳的信號(hào)穩(wěn)定性。附加氣體,例如分析有機(jī)溶劑所需的氧氣,可以很容易地通過(guò)一個(gè)專用進(jìn)氣口添加到等離子體中。
- 附件及聯(lián)用技術(shù)
進(jìn)樣區(qū)域操作方便,可輕松連接到外圍設(shè)備,如激光燒蝕(LA)、離子/液相色譜法(IC/LC)和氣相色譜(GC)系統(tǒng)等。臺(tái)式IC/LC和 GC設(shè)備可以直接放置在 iCAP™ Q ICP源旁邊,最大限度縮短樣品移動(dòng)距離,以減少峰展寬。直接在進(jìn)樣系統(tǒng)附近為外圍設(shè)備提供附加氣體供應(yīng),以實(shí)現(xiàn)高效連接。
- 自動(dòng)進(jìn)樣系統(tǒng) 
全面支持CETAC和ESI的自動(dòng)進(jìn)樣器系統(tǒng)。進(jìn)樣區(qū)域操作十分方便,提供了從任何一款自動(dòng)進(jìn)樣器安全、方便的進(jìn)樣。自動(dòng)進(jìn)樣器可以直接放置在ICP離子源旁邊,縮短進(jìn)樣管長(zhǎng)度,增加樣品通量并最大限度減少樣品交叉污染。
- 提供完整的EPA方法,支持實(shí)驗(yàn)室快速建立符合規(guī)范的方法。包括量身定制的軟件模板和性能報(bào)告,以及完整的文件,從而可以幫助形成標(biāo)準(zhǔn)作業(yè)程序。
提供環(huán)境、臨床、藥物、食品飲料的綜合痕量元素分析解決方案。
該公司產(chǎn)品分類(lèi): 實(shí)驗(yàn)室耗材 標(biāo)準(zhǔn)樣品 樣品前處理系統(tǒng) 物理力學(xué)及測(cè)量 表面分析儀器 輪廓儀 三坐標(biāo)測(cè)量機(jī) 蒸汽吸附儀/蒸氣吸附儀 比表面及孔徑分析儀 激光粒度儀、納米粒度儀 在線粒度儀 研磨機(jī)、研磨儀、粉碎機(jī)、球磨機(jī) 微波消解儀 壓片機(jī) 頂空進(jìn)樣器 液體處理工作站(移液工作站) 濃縮儀 凝膠凈化系統(tǒng)(GPC) X射線能譜儀(EDS) 有機(jī)元素分析儀

鉑鑒GWQ-50供應(yīng)鉑鑒管道彎曲試驗(yàn)機(jī) PVC管彎曲試驗(yàn)機(jī)廠家 金屬管彎曲試驗(yàn)機(jī)制造商

  

應(yīng)鉑鑒管道試驗(yàn)機(jī) PVC試驗(yàn)機(jī)試驗(yàn)機(jī)制造

 

產(chǎn)品性能:GWQ-50鋼管彎曲試驗(yàn)機(jī)是對(duì)金屬管進(jìn)行平面彎曲試驗(yàn)的專用設(shè)備。該設(shè)備是依據(jù)GB/T244-2008 ISO84911998(E)《金屬管彎曲試驗(yàn)方法》開(kāi)發(fā)的新型產(chǎn)品。該產(chǎn)品廣泛應(yīng)用于金屬管廠和管道企業(yè),以檢驗(yàn)金屬管的彎曲性能。 設(shè)備精度可靠,使用方便,限位可靠,使用壽命長(zhǎng),是目前最完善的彎曲試驗(yàn)機(jī)。 鋼管彎曲試驗(yàn)機(jī)產(chǎn)品主要技術(shù)指標(biāo):   1、型號(hào):                GWQ-502、最大彎曲鋼管直徑      40-50 3、正彎角度設(shè)定          180° 4、反彎角度設(shè)定          180°5、工作盤(pán)轉(zhuǎn)速            ≤20°/S 6、鋼管彎曲試驗(yàn)機(jī)工作盤(pán)直徑(mm)       680 7、功率(kW)              1.5 8、外觀:                應(yīng)符合GB/T2611要求9、成套性:              符合標(biāo)準(zhǔn)要求10、供電電源:           220V,50Hz11、主機(jī)外形尺寸(mm   1500×800×2100 12、重量(kg           1000 試驗(yàn)機(jī)的工作條件:1、在室溫10~35范圍內(nèi),相對(duì)濕度不大于80%;2、鋼管彎曲試驗(yàn)機(jī)需在穩(wěn)固的基礎(chǔ)或工作臺(tái)上,正確安裝3、在無(wú)振動(dòng)、無(wú)腐蝕性介質(zhì)及無(wú)較強(qiáng)定磁場(chǎng)干擾的的環(huán)境中;4、電源電壓的波動(dòng)范圍不應(yīng)超過(guò)額定電壓的 +/-10%。

 

 

 

 

鋼管彎曲試驗(yàn)機(jī)     管道彎曲試驗(yàn)機(jī)      PVC彎曲試驗(yàn)機(jī)    金屬管彎曲試驗(yàn)機(jī)     橡膠管不銹鋼管彎曲試驗(yàn)機(jī) 

 

最新產(chǎn)品

熱門(mén)儀器: 液相色譜儀 氣相色譜儀 原子熒光光譜儀 可見(jiàn)分光光度計(jì) 液質(zhì)聯(lián)用儀 壓力試驗(yàn)機(jī) 酸度計(jì)(PH計(jì)) 離心機(jī) 高速離心機(jī) 冷凍離心機(jī) 生物顯微鏡 金相顯微鏡 標(biāo)準(zhǔn)物質(zhì) 生物試劑