1、 焦?fàn)t煤氣氧成份分析系統(tǒng)概述:
焦?fàn)t煤氣氧分析系統(tǒng)由1臺(tái)防爆型氧分析器和1套氣體采樣及預(yù)處理成套系統(tǒng)組成。氣體取樣采用我公司具有技術(shù)的蒸汽引射探頭,并采用蒸汽伴熱管路方式以及預(yù)處理系統(tǒng)全部采用無(wú)電設(shè)備。本方案很好解決了焦?fàn)t煤氣樣氣中的焦油、苯類、粉塵等給取樣帶來(lái)的麻煩和防爆安全的需要。
2、 焦?fàn)t煤氣氧成份分析系統(tǒng)系統(tǒng)適用環(huán)境:
Ø 環(huán)境溫度: -5 ℃~45 ℃
Ø 相對(duì)濕度: < 90%
Ø 電源: 220V ± 10% 50Hz ± 10%
Ø 容量: 不大于 4KVA
Ø 壓縮空氣源: 0.4 — 0.7Mpa
Ø 耗氣量: 每小時(shí)不大于 15m3
3、 焦?fàn)t煤氣氧成份分析系統(tǒng)系統(tǒng)適用工況:焦?fàn)t煤氣電捕焦器
Ø 煙氣溫度: 0 ~ 200 ℃
Ø 煙氣壓力: -10Kpa~+20 Kpa
Ø 粉塵含量:≤ 50g /Nm3
Ø 輸樣管長(zhǎng):< 40m
Ø 有害雜質(zhì):焦油、腐蝕物、結(jié)晶物等
4、 焦?fàn)t煤氣氧成份分析系統(tǒng)氧分析儀技術(shù)指標(biāo)
(1)取樣點(diǎn)位置:焦?fàn)t煤氣電捕焦器出口煤氣
(2)分析參數(shù): O2
(3)測(cè)量原理: 電化學(xué)傳感器
Ø 測(cè)量范圍: 0-3%
Ø 響應(yīng)時(shí)間: <2s
Ø 工作溫度: -5 ℃+ 45 ℃
Ø 線性度: ≤± 0.5 % FS
Ø 零點(diǎn)漂移和量程漂移:≤± 0.5 % FS ( Week )
Ø 環(huán)境濕度: ≤ 90%RH ,不結(jié)露
| ||||||||
LA-S植物圖像分析系統(tǒng)產(chǎn)品說(shuō)明:
該多用途全能型的植物葉面積、根系、年輪、葉色分析儀是一種方便、可在野外或?qū)嶒?yàn)室使用的綜合性分析儀器,精確度遠(yuǎn)高于傳統(tǒng)的分析儀(傳送或基于相機(jī)的類型)。采用全球統(tǒng)一標(biāo)準(zhǔn),可精確、快速、無(wú)損傷地測(cè)定葉片的葉面積和葉色參數(shù),也可對(duì)采摘的植物葉片及其它片狀物體進(jìn)行面積測(cè)量,還可進(jìn)行葉片顏色分析(包括按葉片顏色自動(dòng)分檔查詢,用于植物或作物氮肥狀態(tài)的快速評(píng)價(jià))。系統(tǒng)的植物年輪分析模塊可用于樹木年代學(xué)、年輪生態(tài)環(huán)境變化學(xué)、年輪氣候?qū)W、地理科學(xué)、考古學(xué)研究。植物根系分析模塊為可選模塊,用于洗根后的專業(yè)根系分析,可分析根系長(zhǎng)度、直徑、面積、體積、根尖記數(shù)等,其功能強(qiáng)大,操作簡(jiǎn)單,運(yùn)用于根系形態(tài)和構(gòu)造研究。該儀器綜合了植物、農(nóng)作物在葉面積、根系、年輪、葉色這4大方面的分析功能,廣泛適用于農(nóng)業(yè)、林業(yè)、氣象等部門。技術(shù)參數(shù):◆葉分析測(cè)量參數(shù):葉面積 (可累計(jì)面積)、葉片面積(可累計(jì)面積)、葉子穿孔面積 (可累計(jì)面積)、葉片長(zhǎng)度和寬度、葉柄長(zhǎng)度、葉周長(zhǎng) (不受葉片孔洞影響)、葉片周長(zhǎng)、葉片長(zhǎng)寬比、葉片形狀系數(shù)、自定義長(zhǎng)度和角度測(cè)量,葉片鋸齒高度、寬度、數(shù)量測(cè)量,葉孔面積測(cè)量;包膜(齒-齒之間的直線長(zhǎng)度和),包膜形成的投影面積;不規(guī)則葉片形態(tài)分析,輔助真彩病理分析,葉片顏色分析(包括按葉片顏色自動(dòng)分檔查詢,用于氮肥狀態(tài)的外觀評(píng)價(jià))。
◆植物年輪測(cè)量分析:可自動(dòng)判讀年輪數(shù)、各年輪平均寬度、早材及晚材寬度、各年輪切向角度和面積?勺詣(dòng)劃分出年輪邊界、早材邊界、晚材邊界,以及識(shí)別出很窄的樹輪,可交互刪除偽年輪、插入斷年輪。分析獲得的測(cè)量數(shù)據(jù)具備進(jìn)一步做交叉定年、生成年表、數(shù)據(jù)分析處理能力。◆植物根系可分析測(cè)量:1)根總長(zhǎng);2)根平均直徑;3)根總面積;4)根總體積;5)根尖計(jì)數(shù);6)分叉計(jì)數(shù);7)交疊計(jì)數(shù);8)根直徑等級(jí)分布參數(shù),等。匹配專門的雙光源照明系統(tǒng),提供高分辨率的彩色或黑白圖像,去除了陰影和不均勻現(xiàn)象的影響,有效保證圖像質(zhì)量。采用非統(tǒng)計(jì)學(xué)方法測(cè)量計(jì)算出交叉重疊部分根系長(zhǎng)度等,可讀取處理TIFF、BMP、JPEG標(biāo)準(zhǔn)格式的圖像。植物葉面積分析 植物葉色比對(duì)分檔
植物年輪分析1 植物年輪分析2
植物根系分析1 植物根系分析2
實(shí)驗(yàn)室建設(shè)原則參考普通環(huán)境標(biāo)準(zhǔn),該環(huán)境設(shè)施符合動(dòng)物居住的基本要求,不能完全控制傳染因子,適用于飼養(yǎng)教學(xué)等用途的普通實(shí)驗(yàn)動(dòng)物。
1. 給水排水系統(tǒng):上水水壓0.3-0.5MPa,冷熱水分別獨(dú)立提供;實(shí)驗(yàn)室下水口距地面高度低于10cm。動(dòng)物行為學(xué)視頻分析系統(tǒng),行為學(xué)實(shí)驗(yàn)站 HB
2. 實(shí)驗(yàn)室內(nèi)光照度:室內(nèi)光照度恒定,阻斷室外光線(隔光窗簾或無(wú)窗戶),室內(nèi)光源由室內(nèi)燈提供,分為實(shí)驗(yàn)光源和工作光源,實(shí)驗(yàn)光源根據(jù)不同實(shí)驗(yàn)設(shè)備專門布置射燈位置及角度,實(shí)驗(yàn)時(shí)保持實(shí)驗(yàn)光源提供的光照度恒定不變(可以用光照計(jì)測(cè)量);工作光源漫反射光源,照度為150-300LX.
3. 動(dòng)物房光線:動(dòng)物房?jī)?nèi)要有較亮的工作光線和較暗的生活光線調(diào)節(jié);要裝有晝夜明暗交替照明系統(tǒng),每12h輪轉(zhuǎn)照明,工作照度150-300LX,動(dòng)物照度15-20LX,調(diào)節(jié)實(shí)驗(yàn)動(dòng)物節(jié)律跟人類一致。
4. 通風(fēng):實(shí)驗(yàn)動(dòng)物一般對(duì)氣味非常敏感,所以實(shí)驗(yàn)室、動(dòng)物房要有獨(dú)立的通風(fēng)系統(tǒng),換氣次數(shù)8-10次/h,氣流速度0.1-0.2m/s(最好是從籠子里出來(lái)直接排到室外,而不是排到室內(nèi))。動(dòng)物行為學(xué)視頻分析系統(tǒng),行為學(xué)實(shí)驗(yàn)站 HB
5. 隔音:實(shí)驗(yàn)室建設(shè)初期可在四周墻壁中加裝隔音層或者后期加裝波峰海綿,室內(nèi)噪音低于60dB(也可購(gòu)置專門的隔音箱)。
6. 溫度:室內(nèi)溫度恒定19~26℃為宜(日溫差小于4℃),推薦20~25℃(日溫差小于3℃),冷熱雙制空調(diào)系統(tǒng)是必需的。
7. 相對(duì)濕度控制在40%~70%較好。
8. 動(dòng)物房距離實(shí)驗(yàn)室的距離因在同一隔離區(qū)域內(nèi),實(shí)驗(yàn)動(dòng)物繁育、生產(chǎn)、實(shí)驗(yàn)設(shè)施應(yīng)與生活區(qū)保持大于50m的距離,盡量避免實(shí)驗(yàn)動(dòng)物的搬運(yùn)過(guò)程接觸外界。
9. 實(shí)驗(yàn)過(guò)程中禁止實(shí)驗(yàn)人員或其他人員在實(shí)驗(yàn)室內(nèi)或?qū)嶒?yàn)室門外頻繁進(jìn)出,避免在同一間實(shí)驗(yàn)室內(nèi)同時(shí)進(jìn)行兩項(xiàng)或兩項(xiàng)以上的實(shí)驗(yàn),去除實(shí)驗(yàn)人員對(duì)實(shí)驗(yàn)動(dòng)物的影響。
10. 動(dòng)物行為學(xué)實(shí)驗(yàn)設(shè)備一般體積較大、數(shù)量較多,實(shí)驗(yàn)室空間根據(jù)實(shí)驗(yàn)設(shè)備的要求定制和設(shè)計(jì)實(shí)驗(yàn)場(chǎng)地。
11. 實(shí)驗(yàn)室的電腦操作室要求獨(dú)立一個(gè)房間,避免影響實(shí)驗(yàn)。
12. 每套電腦因單獨(dú)控制一套設(shè)備為宜。
13. 實(shí)驗(yàn)室最好配置恒定白噪音發(fā)生器(避免外界和動(dòng)物間的聲音干擾)
14. 實(shí)驗(yàn)室的電氣指標(biāo)要求三廂,可拼配接20A電流。實(shí)驗(yàn)室因配置UPS設(shè)備,保證實(shí)驗(yàn)室供電穩(wěn)定性保證實(shí)驗(yàn)正常進(jìn)行
15. 走廊寬度不應(yīng)少于1.5m,門寬度不少于1.0m,房高不能低于2.8m。
二、服務(wù)計(jì)劃
1) 培訓(xùn)計(jì)劃
① 安裝及基本維護(hù)公司派技術(shù)人員一名,至現(xiàn)場(chǎng)介紹震驚條件反射分析系統(tǒng)等設(shè)備的各個(gè)組成部分,并演示系統(tǒng)的軟硬件安裝及使用系統(tǒng)時(shí)需要注意的各個(gè)事項(xiàng)。并由用戶親自動(dòng)手拆卸、安裝系統(tǒng)一次,公司培訓(xùn)人員在旁指導(dǎo)。
② 軟件的操作:基本操作、高級(jí)操作重點(diǎn)介紹各個(gè)系統(tǒng)的軟件基本操作和高級(jí)操作;静僮鞯呐嘤(xùn)以達(dá)到用戶能熟練使用本系統(tǒng),能夠進(jìn)行實(shí)際的實(shí)驗(yàn),得到實(shí)驗(yàn)結(jié)果。高級(jí)操作的培訓(xùn)包括本系統(tǒng)的基本原理、參數(shù)的設(shè)置、意義及適用場(chǎng)合,以及出現(xiàn)特殊情況時(shí)的應(yīng)變方法。
③ 實(shí)驗(yàn)SOP培訓(xùn)演示各個(gè)系統(tǒng)標(biāo)準(zhǔn)試驗(yàn)流程,并進(jìn)行演示性實(shí)驗(yàn),掌握本系統(tǒng)的實(shí)際操作過(guò)程
④ 實(shí)際操作及答疑問(wèn)每套系統(tǒng)設(shè)計(jì)安排一個(gè)具體的實(shí)驗(yàn),用戶實(shí)際進(jìn)行操作,觀查分析實(shí)驗(yàn)結(jié)果,公司培訓(xùn)人員現(xiàn)場(chǎng)指導(dǎo),并隨時(shí)解答問(wèn)題。
系統(tǒng)由筆記本計(jì)算機(jī)+精密測(cè)量系統(tǒng)+聲強(qiáng)探頭+Windows平臺(tái)的聲強(qiáng)測(cè)量分析軟件組成,總重量不到5kg?梢砸罁(jù)ISO9614-1和ISO9614-2在普通聲學(xué)環(huán)境中得測(cè)定聲源和各種設(shè)備的聲功率,從而可節(jié)約一大筆建造消聲室的費(fèi)用,并且可以完成諸多在消聲室內(nèi)使用聲壓法無(wú)法完成的測(cè)量工作。主要測(cè)量功能: 聲強(qiáng)測(cè)量、聲壓測(cè)量、聲功率測(cè)量、時(shí)域示波、短/瞬時(shí)聲功率測(cè)量和聲場(chǎng)指示值測(cè)量。實(shí)時(shí)數(shù)據(jù)采集功能確保對(duì)瞬態(tài)信號(hào)的實(shí)時(shí)捕捉,以便用于聲學(xué)研究領(lǐng)域。系統(tǒng)使用基于FFT的互譜聲強(qiáng)測(cè)量分析技術(shù),提供的的窄帶譜分析功能,還有A/B/C/D任意計(jì)權(quán)分析,1/1、1/2、1/3···任意倍頻程合成以及等聲強(qiáng)線和三維聲強(qiáng)譜擬合等。主要技術(shù)參數(shù):1、測(cè)量聲級(jí)范圍:30~120dB;2、頻率:10kHz;示波頻率范圍:0~25kHz;3、程控放大倍數(shù):1~1.7E4;增益誤差:小于0.01dB;4、系統(tǒng)相位誤差:1kHz內(nèi)小于0.1度;全頻帶小于0.3度(不包括傳聲器),校正后小于0.1度。Sound Intensity Measurement and Analysis System Using Cross-Spectral Method This new system is composed of a notebook PC,an accurate measurement device,a sound intensity probe and analysis software based on the Windows platform with a weight of less than 5kg.It can be used to measure sound power of a sourcer accurately in a common acoustic environment according to ISO9614-1 and ISO9614-2,which saves a large amount of money for building an anechoic chamber. More over,it can perform many that can`t be done in an anechoic chamber.Main measurement functions: Sound pressure measurement,sound intensity measurement, sound power measurement, time field wave display, instantaneous sound power measurement and sound field indicator measurement. Real time sampling fuction easures the capture of an instantaneous signal, which may be used for the acoustic research work.The cross-spectral method based on FFT is used in the system, which offers an accurate narrow band analysis,A,B,C and D weighting, and 1/1,1/2.1/3 etc. octave synthesizing, and three-dimension plotting are offered too.Main Technical Specifications:1.Valid sound level range: 30dB to 120dB;2.Valid maximun frequency: 10kHz, frequency range for wave display:0 to 25kHz;3.Gain of the programmable amplifier:1 to 1.7E4 times, gain error:0.01dB max;4.Phase error (not exclude the microphones`s):0.1degree max for below 1kHz, 0.3degee max for full frequency range, all below 0.1degree after adjusting.
主要功能與技術(shù)指標(biāo): 1.葉分析測(cè)量參數(shù):葉面積 (可累計(jì)面積)、葉片面積(可累計(jì)面積)、葉子穿孔面積 (可累計(jì)面積)、葉片長(zhǎng)度和寬度、葉柄長(zhǎng)度、葉周長(zhǎng) (不受葉片孔洞影響)、葉片周長(zhǎng)、葉片長(zhǎng)寬比、葉片形狀系數(shù)、自定義長(zhǎng)度和角度測(cè)量,葉片鋸齒高度、寬度、數(shù)量測(cè)量,葉孔面積測(cè)量;包膜(齒-齒之間的直線長(zhǎng)度和),包膜形成的投影面積;不規(guī)則葉片形態(tài)分析,輔助真彩病理分析,葉片顏色分析(包括按葉片顏色自動(dòng)分檔查詢,用于氮肥狀態(tài)的外觀評(píng)價(jià))。
植物葉面積分析 | 植物葉色比對(duì)分檔 |
植物年輪分析1 | 植物年輪分析2 |
植物根系分析1 | 植物根系分析2 |
1概述 5.10分項(xiàng)能耗分析 現(xiàn)代醫(yī)院對(duì)建筑裝潢、溫濕度控制、空氣潔凈度、環(huán)境安全和信息自動(dòng)化都有很高的要求。醫(yī)院建筑是所有建筑中使用功能最為復(fù)雜、安全性要求最高的建筑之一。醫(yī)療環(huán)境質(zhì)量的提高,勢(shì)必增加醫(yī)院的運(yùn)營(yíng)能耗,三甲綜合性醫(yī)院尤其如此。醫(yī)院能耗是一般公共建筑的1.6~2倍,醫(yī)院建筑節(jié)能潛力巨大。醫(yī)院要節(jié)能,首先要了解醫(yī)院建筑能耗的構(gòu)成,及其能耗的特點(diǎn)。 綜合性醫(yī)院日常能耗中,電力消耗最大,主要用于照明、空調(diào)和通風(fēng)、電梯、給水等設(shè)備。其次,醫(yī)院還以燃?xì)、重油等作為主要能源,用于供?yīng)蒸汽、熱水、消毒、洗滌、廚房以及冬季供暖等。而在電力消耗中,空調(diào)系統(tǒng)用電的比例超過(guò)50%。 Acrel-5000能耗分析與能源管理系統(tǒng)通過(guò)對(duì)醫(yī)院建筑具體進(jìn)行詳細(xì)的能耗分析,安裝分類分項(xiàng)智能能耗計(jì)量裝置,采用遠(yuǎn)程傳輸?shù)仁侄渭皶r(shí)采集能耗數(shù)據(jù),實(shí)現(xiàn)建筑能耗的在線監(jiān)測(cè)和動(dòng)態(tài)分析,在保證供電可靠性并且不減少病人和醫(yī)務(wù)人員的舒適體驗(yàn)前提下,通過(guò)能耗分析和管理,大大減少醫(yī)院建筑的能耗。三甲醫(yī)院節(jié)能潛力大,是建筑節(jié)能的重點(diǎn)領(lǐng)域。節(jié)能的前提是掌握詳細(xì)、分項(xiàng)的能耗數(shù)據(jù),通過(guò)數(shù)據(jù)分析提高醫(yī)院的能源使用效率。 2系統(tǒng)特點(diǎn)對(duì)主要能耗設(shè)備進(jìn)行實(shí)時(shí)跟蹤,計(jì)算中央空調(diào)實(shí)時(shí)的COP值并繪制COP曲線 集成各類儀表通信協(xié)議,可對(duì)各類型能耗數(shù)據(jù)進(jìn)行采集; 建立醫(yī)院的能耗計(jì)量體系,對(duì)建筑能耗實(shí)現(xiàn)“CT式”管理; 通過(guò)能耗數(shù)據(jù)分析,發(fā)現(xiàn)能耗黑洞; 為節(jié)能改造指明方向,并驗(yàn)證節(jié)能效果; 橫向比較相同類型建筑的能耗數(shù)據(jù),通過(guò)能耗公示鼓勵(lì)先進(jìn)、督促落后; 數(shù)據(jù)傳輸采用MD5認(rèn)證算法以及AES加密算法,保證信息傳輸?shù)目煽啃浴⒈C苄浴?/p> 3系統(tǒng)結(jié)構(gòu) 系統(tǒng)根據(jù)具體的工程情況來(lái)組網(wǎng),采用分層分布式結(jié)構(gòu)。 根據(jù)項(xiàng)目規(guī)模的大小,可以靈活選擇通訊介質(zhì)和組網(wǎng)方式。當(dāng)設(shè)備比較集中時(shí),通訊介質(zhì)通常采用屏蔽雙絞線和五類八芯屏蔽電纜;當(dāng)系統(tǒng)設(shè)備比較分散時(shí),可采用光纖作為通訊介質(zhì),組網(wǎng)方式可以采用光纖環(huán)網(wǎng)或者光纖星型網(wǎng);如果設(shè)備較少而且非常分散,可以采用無(wú)線通訊設(shè)備組網(wǎng)。 由于醫(yī)院建筑規(guī)模比較大,設(shè)備數(shù)量多而且安裝比較分散,我們采用光纖環(huán)網(wǎng)模式進(jìn)行組網(wǎng),組網(wǎng)示意圖如圖1所示: ![]() 圖2 醫(yī)院能耗分類分項(xiàng)統(tǒng)計(jì)示意圖
![]() 圖4用能趨勢(shì)分析圖 通過(guò)用能趨勢(shì)圖,快速定位用能負(fù)荷高峰,并逐級(jí)定位高峰能耗的組成,為移峰填谷找到依據(jù)。 5.3節(jié)能足跡圖5能耗對(duì)比圖 記錄每一次節(jié)能改造的過(guò)程和記錄,通過(guò)改造后的同比分析,使原來(lái)無(wú)法說(shuō)清楚的節(jié)能改造效果變得可量化、可比較、可評(píng)價(jià),展示節(jié)能工作所取得的成果。 5.4報(bào)表服務(wù)圖6 能耗報(bào)表圖 按需定制的各類報(bào)表,包括分戶能耗、設(shè)備能耗、數(shù)據(jù)集抄等,并可將數(shù)據(jù)導(dǎo)出到Excel等電子文件,方便日常管理工作。 5.5 CS和BS兩種訪問(wèn)方式圖7 系統(tǒng)訪問(wèn)方式圖 系統(tǒng)提供C/S和B/S兩種訪問(wèn)模式,C/S訪問(wèn)模式客戶端響應(yīng)速度快,充分發(fā)揮客戶端PC的處理能力,減輕服務(wù)器的壓力。B/S訪問(wèn)模式不需要安裝客戶端,任何地方只要有一臺(tái)可以上網(wǎng)的電腦即可訪問(wèn)服務(wù)器,做到了真正的跨網(wǎng)絡(luò)、跨平臺(tái)訪問(wèn)。 5.6系統(tǒng)靈活擴(kuò)展圖8 系統(tǒng)配置圖 系統(tǒng)可根據(jù)醫(yī)院實(shí)際用能情況,靈活配置用能類型、用能結(jié)構(gòu)、用能設(shè)備、用能區(qū)域、監(jiān)測(cè)參量等基本信息,對(duì)系統(tǒng)上線后發(fā)生的用能回路、用能設(shè)備的增加亦只需進(jìn)行配置即可。系統(tǒng)可以通過(guò)互聯(lián)網(wǎng)接入單個(gè)或多個(gè)單位的用能情況,進(jìn)行集中管理。 5.7集團(tuán)式能耗管理模式系統(tǒng)將歸屬同一集團(tuán)、同一區(qū)域的單位的GPS坐標(biāo)標(biāo)注在電子地圖上,鼠標(biāo)停靠在坐標(biāo)上可顯示該企業(yè)的能耗概況,雙擊圖標(biāo)后可顯示企業(yè)用能的詳細(xì)情況,方便集團(tuán)公司對(duì)下屬分公司、門店進(jìn)行集中管控。 5.8遠(yuǎn)程集抄將分散分布的能源監(jiān)測(cè)計(jì)量表具通過(guò)能源管理系統(tǒng)連接在一起,各表數(shù)據(jù)采集時(shí)間偏差十分微小,大大減輕人工抄表的工作量,實(shí)現(xiàn)“能耗信息采集自動(dòng)化、數(shù)據(jù)傳輸網(wǎng)絡(luò)化、管理數(shù)字量化、決策科學(xué)化”的目標(biāo)。 5.9電能質(zhì)量管理![]() 圖9 電能質(zhì)量管理圖 通過(guò)與電能管理系統(tǒng)的數(shù)據(jù)接口,可將電能管理中的數(shù)據(jù)引入到能耗系統(tǒng)中進(jìn)行分析,包括三相電流、三相電壓、功率、功率因素、諧波等。 圖10 分項(xiàng)能耗分析圖 將各類能源監(jiān)測(cè)數(shù)據(jù)(水、電、氣)接入到一套能耗監(jiān)測(cè)系統(tǒng)中,改變?cè)瓉?lái)多頭管理的局面,清晰的掌握企業(yè)能耗的構(gòu)成,避免能耗改造過(guò)程中降低某一類能耗的同時(shí)增加了其他類能耗的支出。 5.11用能分時(shí)段統(tǒng)計(jì)
![]() 圖12 多維度用能分析圖 判斷一個(gè)能耗的高低,不應(yīng)僅僅看總量,還應(yīng)將能耗數(shù)據(jù)同建筑面積、員工人數(shù)、商場(chǎng)客流量、產(chǎn)量、銷售額、環(huán)境溫度等其他參數(shù)進(jìn)行綜合比較,系統(tǒng)可以根據(jù)需要建立不同的能耗分析模型,從而更加科學(xué)、更加準(zhǔn)確的判斷建筑能耗的高低。 |
想了解更多,請(qǐng)聯(lián)系我們! 公司:安科瑞電氣股份有限公司 [股票代碼:300286.SZ] 銷售:任華 手機(jī):13817237723 電話:021-59104851 Q Q:2880 157 851 網(wǎng)址:http://www.acrel-em.com/ 地址:上海市嘉定馬東工業(yè)園區(qū)育綠路253號(hào) |
4700TOF/TOF蛋白質(zhì)組分析系統(tǒng)是全球臺(tái)TOF/TOF 串聯(lián)飛行質(zhì)譜儀,它作為目前的質(zhì)譜技術(shù),它一問(wèn)世即被世界各大蛋白組研究中心和蛋白質(zhì)實(shí)驗(yàn)室所爭(zhēng)相采用。它由兩級(jí)TOF和高能碰撞池組成,其工作原理是離子在MALDI源中產(chǎn)生并被加速和聚焦;對(duì)于MS/MS 模式可通過(guò)級(jí)TOF選擇母離子進(jìn)入高能碰撞池中碰碎,然后進(jìn)入第二級(jí)TOF重新被加速并被分析。 回首ABI 3700 DNA快速測(cè)序儀給基因組學(xué)帶來(lái)革命性的影響,4700蛋白質(zhì)組分析儀必將給后基因組學(xué)的研究帶來(lái)同樣的革命性影響。4700 TOF/TOF系統(tǒng)現(xiàn)已成為蛋白組研究的最前沿核心工具。 |